|
How to Manage Pests
Description of Robbins-06.P
(SUT3)
|
PestCast Network(s)2002 California Tomato
Observer
Mike Cahn
Location
Mackert and Reclamation Road
County: Sutter
Nearest City: Robbins
Latitude: 38 deg
50 min N
Longitude: 121 deg
41 min W
Elevation: 33 ft
Station and site characteristics
Manufacturer/model: Campbell Scientific Inc. CR-10 ( or CR-10X)
Crop: Processing tomatoes
Available data
UC IPM database records begin/end: June 18, 2002
/ August 27, 2002
Reporting interval: 30 minute, Hourly, Daily
Stored variables:
Air Temperature, max/min:
HMP35/45C temp-RH probe
Air Temperature 3, max/min:
HMP35/45C temp-RH probe
Air Temperature, average:
HMP35/45C temp-RH probe
Air Temperature 3, average:
HMP35/45C temp-RH probe
Growing Degree Days:
Calculated degree-days (thresholds: 41 F, 97 F) from air temps
Growing Degree Days 3:
Calculated degree-days (thresholds: 41 F, 97 F) from air temps
Temperature Threshold Hours:
Hours between 65 F and 75 F with RH > 90%
Temperature Threshold Hours 3:
Hours between 65 F and 75 F with RH > 90%
Leaf wetness:
237 resistance grid
Leaf wetness 3:
237 resistance grid
Relative Humidity, max/min:
HMP35/45C temp-RH probe
Relative Humidity, average:
HMP35/45C temp-RH probe
Relative Humidity 3, average:
HMP35/45C temp-RH probe
TomCast DSV:
Calculated TOM-CAST DSV from leaf wetness and air temp
TomCast DSV 3:
Calculated TOM-CAST DSV from leaf wetness and air temp
Variables with computed averages: none
Details about reported variables
Air Temperature, max/min
Variable or Sensor: |
HMP35/45C temp-RH probe |
Height of Sensor: |
plant height |
Sensor Setup: |
in canopy |
When Installed: |
01 April 1999 |
Comment: |
Location is in tomato field. |
Reporting Intervals: |
Daily, Hourly |
Air Temperature 3, max/min
Variable or Sensor: |
HMP35/45C temp-RH probe |
Height of Sensor: |
1.5 meters |
Sensor Setup: |
above crop at 1.5 meters above ground |
When Installed: |
01 April 1999 |
Comment: |
Location is in tomato field. |
Reporting Intervals: |
Daily |
Air Temperature, average
Variable or Sensor: |
HMP35/45C temp-RH probe |
Height of Sensor: |
plant height |
Sensor Setup: |
in canopy |
When Installed: |
01 April 1999 |
Comment: |
Location is in tomato field. |
Reporting Intervals: |
Daily, Hourly, 30 minute |
Air Temperature 3, average
Variable or Sensor: |
HMP35/45C temp-RH probe |
Height of Sensor: |
1.5 meters |
Sensor Setup: |
above crop at 1.5 meters above ground |
When Installed: |
01 April 1999 |
Comment: |
Location is in tomato field. |
Reporting Intervals: |
Daily, Hourly, 30 minute |
Growing Degree Days
Variable or Sensor: |
Calculated degree-days (thresholds: 41 F, 97 F) from air temps |
Sensor Setup: |
in canopy |
Reporting Intervals: |
Daily |
Growing Degree Days 3
Variable or Sensor: |
Calculated degree-days (thresholds: 41 F, 97 F) from air temps |
Sensor Setup: |
above crop at 1.5 meters above ground |
Reporting Intervals: |
Daily |
Temperature Threshold Hours
Variable or Sensor: |
Hours between 65 F and 75 F with RH > 90% |
Sensor Setup: |
in canopy |
Reporting Intervals: |
Daily |
Temperature Threshold Hours 3
Variable or Sensor: |
Hours between 65 F and 75 F with RH > 90% |
Sensor Setup: |
above crop at 1.5 meters above ground |
Reporting Intervals: |
Daily |
Leaf wetness
Variable or Sensor: |
237 resistance grid |
Height of Sensor: |
plant height |
Sensor Setup: |
in canopy |
When Installed: |
01 April 1999 |
Reporting Intervals: |
Daily, Hourly, 30 minute |
Leaf wetness 3
Variable or Sensor: |
237 resistance grid |
Height of Sensor: |
1.5 meters |
Sensor Setup: |
above crop at 1.5 meters above ground |
When Installed: |
01 April 1999 |
Comment: |
Location is in tomato field. |
Reporting Intervals: |
Daily, Hourly, 30 minute |
Relative Humidity, max/min
Variable or Sensor: |
HMP35/45C temp-RH probe |
Sensor Setup: |
in canopy |
When Installed: |
22 March 2002 |
Comment: |
Location is in tomato field. |
Reporting Intervals: |
Hourly |
Relative Humidity, average
Variable or Sensor: |
HMP35/45C temp-RH probe |
Sensor Setup: |
in canopy |
When Installed: |
01 April 1999 |
Comment: |
Location is in tomato field. |
Reporting Intervals: |
Daily, Hourly, 30 minute |
Relative Humidity 3, average
Variable or Sensor: |
HMP35/45C temp-RH probe |
Height of Sensor: |
1.5 meters |
Sensor Setup: |
above crop at 1.5 meters above ground |
When Installed: |
01 April 1999 |
Comment: |
Location is in tomato field. |
Reporting Intervals: |
Daily, Hourly, 30 minute |
TomCast DSV
Variable or Sensor: |
Calculated TOM-CAST DSV from leaf wetness and air temp |
Sensor Setup: |
in canopy |
Reporting Intervals: |
Daily |
TomCast DSV 3
Variable or Sensor: |
Calculated TOM-CAST DSV from leaf wetness and air temp |
Sensor Setup: |
above crop at 1.5 meters above ground |
Reporting Intervals: |
Daily |
Top of page
|