How to Manage Pests
Description of Rindge_Tract-03.P
(CTR1)
|
PestCast Network(s)2003 California Tomato
Observer
CTRI
Location
Near Blackslough Landing and Rindge Tract Road
County: San Joaquin
Nearest City: Stockton
Latitude: 38 deg
00 min N
Longitude: 121 deg
26 min W
Elevation: 0 ft
Station and site characteristics
Manufacturer/model: Campbell Scientific Inc. CR-10 ( or CR-10X)
Crop: Processing tomatoes
Available data
UC IPM database records begin/end: July 16, 2003
/ September 25, 2003
Reporting interval: 30 minute, Hourly, Daily
Stored variables:
Air Temperature, max/min:
HMP35/45C temp-RH probe
Air Temperature, average:
HMP35/45C temp-RH probe
Growing Degree Days:
Calculated degree-days (thresholds: 41 F, 97 F) from air temps
Temperature Threshold Hours:
Hours between 65 F and 75 F with RH > 90%
Leaf wetness:
237 resistance grid
Relative Humidity, max/min:
HMP35/45C temp-RH probe
Relative Humidity, average:
HMP35/45C temp-RH probe
TomCast DSV:
Calculated TOM-CAST DSV from leaf wetness and air temp
Variables with computed averages: none
Details about reported variables
Air Temperature, max/min
Variable or Sensor: |
HMP35/45C temp-RH probe |
Height of Sensor: |
plant height |
Sensor Setup: |
in canopy |
When Installed: |
15 July 2003 |
Comment: |
Location is in tomato field. |
Reporting Intervals: |
Daily, Hourly |
Air Temperature, average
Variable or Sensor: |
HMP35/45C temp-RH probe |
Height of Sensor: |
plant height |
Sensor Setup: |
in canopy |
When Installed: |
15 July 2003 |
Comment: |
Location is in tomato field. |
Reporting Intervals: |
Daily, Hourly, 30 minute |
Growing Degree Days
Variable or Sensor: |
Calculated degree-days (thresholds: 41 F, 97 F) from air temps |
Sensor Setup: |
in canopy |
Reporting Intervals: |
Daily |
Temperature Threshold Hours
Variable or Sensor: |
Hours between 65 F and 75 F with RH > 90% |
Sensor Setup: |
in canopy |
Reporting Intervals: |
Daily |
Leaf wetness
Variable or Sensor: |
237 resistance grid |
Height of Sensor: |
plant height |
Sensor Setup: |
in canopy |
When Installed: |
15 July 2003 |
Reporting Intervals: |
Daily, Hourly, 30 minute |
Relative Humidity, max/min
Variable or Sensor: |
HMP35/45C temp-RH probe |
Sensor Setup: |
in canopy |
When Installed: |
15 July 2003 |
Comment: |
Location is in tomato field. |
Reporting Intervals: |
Hourly |
Relative Humidity, average
Variable or Sensor: |
HMP35/45C temp-RH probe |
Sensor Setup: |
in canopy |
When Installed: |
15 July 2003 |
Comment: |
Location is in tomato field. |
Reporting Intervals: |
Daily, Hourly, 30 minute |
TomCast DSV
Variable or Sensor: |
Calculated TOM-CAST DSV from leaf wetness and air temp |
Sensor Setup: |
in canopy |
Reporting Intervals: |
Daily |
Top of page
|